Localized formatting of dates and numbers in French has been added. Thanks to Luc Rochefort and colleagues for this contribution.
Saxon now checks that all the documents involved in a query or transformation were built under the same
Configuration
. Previously this was not always checked; the consequence of breaking this rule was
that documents in different configurations could used the same document numbers and thus
be considered to have the same identity, causing incorrect results for operations that are sensitive to
node identity, for example elimination of duplicates in a path expression. Note that some of the issued
API sample applications have required changing as a result of these stricter checks.
The PreparedSchema
object now has methods allowing the application to iterate over all the components
in a schema: previously it was only possible to retrieve components by name.
On the Transform
command line, it is now possible to nominate an OutputURIResolver
using
the new -or option.
Casting of a QName to a QName (typically a type derived from QName) and from a NOTATION to a NOTATION is now supported. This is a late change in the specification: see W3C bugzilla entry 2678.
In many cases the error that occurs when an attribute node is added to an element after adding child nodes (such as elements or text nodes) to the parent element is now detected statically. This also applies to the error that occurs when an attribute node is added directly to a document node. The change affects both XSLT and XQuery.
When reading input using a StAX parser, (a) ignorable whitespace is now recognized (if reported by the parser)
and stripped according to the configuration settings in use, and (b) unparsed entities are recognized and reported,
so they are available to the XSLT functions unparsed-entity-uri()
and unparsed-entity-public-id()
.
When a Saxon tree is accessed using DOM interfaces (using the NodeOverNodeInfo
wrapper), namespace nodes
in the Saxon tree are now presented as attributes in the DOM interface.
If an unknown encoding is requested, the transformation now fails with error SESU0007 as defined in the serialization specification. Previously Saxon used ASCII as a fallback. Similarly, error SESU0013 is raised if the HTML output method is used with the version parameter set to a value other than "4.0" or "4.01".
The DocumentBuilderImpl
class, which is Saxon's implementation of the JAXP DocumentBuilder
interface, now has additional non-JAXP methods allowing a Configuration
to be supplied. It is
necessary to register a Configuration
if the new document is to be used within a query or
transformation, to ensure that it has a unique identity and uses the same NamePool
. Saxon
now checks that a document (whatever the object model) that is supplied as input to a query or transformation
uses the same Configuration
as that query or transformation.
The ContentHandlerProxy
class no longer implements Locator
directly; instead it provides this service
through a separate class ContentHandlerProxyLocator
. This change is made because ContentHandlerProxy
previously implemented both Receiver
and Locator
, both of which had a getSystemId()
method, and there was a tension between the semantics of the
two methods.
It is now possible to specify at compile time that tracing is to be compiled in to the executable code, without
specifying a TraceListener
until run-time. This is a more sensible approach when the compiled code
is executed repeatedly.
The serialization pipeline now processes cdata-section-elements
before processing character
maps, as required by the latest revision of the specification. This means that characters in an element where
CDATA sections are used are not subject to character mapping.
It is now possible to customize the serialization pipeline. A SerializerFactory
can be registered with the
Configuration
, subclassing the standard SerializerFactory
, and by overriding methods in the standard
SerializerFactory
it is possible to replace any of the components of the serialization pipeline with
customized subclasses; it is also possible to replace the entire pipeline, should you wish to.